The all-rounder for concrete, masonry and post-installed rebar connections

The all-rounder for concrete, masonry and post-installed rebar connections

Two-part reactive resin mortar, styrene-free vinylester

Individual fixing point, cracked and uncracked concrete, seismic performance category C1

Anchor rod W-VI-A, anchor rod W-VD-A, standard threaded rod with acceptance test certificate 3.1

Masonry individual fixing point (system with perforated sleeve WIT-SH):

Perforated sleeve WIT-SH, anchor rod WIT-AS, internally threaded sleeve WIT-IG

Masonry individual fixing point (system with perforated sleeve SH):

Perforated sleeve SH, anchor rod W-VI-A, standard threaded rod with acceptance certificate 3.1

Post-installed rebar connection

A 330 ml and 420 ml cartridge can continue to be used until the best before date, by changing the static mixer or resealing it with the end cap

Proof of Performance

  • European Technical Assessment ETA-12/0164: Individual fixing point + cracked and uncracked concrete (anchor rod W-VD-A, standard threaded rod with acceptance test certificate 3.1), seismic performance category C1
  • European Technical Assessment ETA-13/1040: Individual fixing point + masonry consisting of solid and perforated brick, aerated concrete (perforated sleeve WIT-SH, anchor rod WIT-AS, internally threaded sleeve WIT-IG, aerated concrete only with perforated sleeve WIT-SH 18x95)
  • European Technical Assessment ETA-16/0757 and ETA-20/0854: Individual fixing point + masonry consisting of solid and perforated brick, aerated concrete (perforated sleeve SH, anchor rod W-VI-A, internally threaded sleeve, threaded rod with acceptance test certificate 3.1, aerated concrete only without perforated sleeve)
  • European Technical Assessment ETA-12/0166: Post-installed rebar connection, 330 ml, 420 ml, 825 ml cartridges only

 

Application area

  • Awnings
  • Steel supports
  • Brackets
  • French balconies
  • Create the drill hole
  • Clean the drill hole: 4x blow-out/4x mechanical brush-out/4x blow-out, effective anchorage depth > 240 mm drill hole with oil-free compressed air, min. 6 bar blow-out pressure
  • Place the embedment depth mark on the rod and check the drilling hole depth
  • Screw mixer onto cartridge
  • Discard the first section of mortar (until the mortar is uniformly coloured - approx. 10 cm)
  • Mount injection equipment, fill injection mortar from bottom of drill hole
  • Insert the reinforcement bar until it reaches the mark, turning slightly
  • Visual check of the mortar volume, observe maximum processing time
  • Load can be applied to the reinforcement bar after observing the curing time
  • Tubular film cartridge, 300 ml: Cut tubular film clip before use! First section of mortar approx. 20 cm
  • Tubular film cartridge, 300 ml: Cut tubular film clip before use! First section of mortar approx. 20 cm

European Technical Assessment ETA-12/0164: Individual fixing point + cracked and uncracked concrete (anchor rod W-VD-A, standard threaded rod with acceptance test certificate 3.1), seismic performance category C1

European Technical Assessment ETA-13/1040: Individual fixing point + masonry consisting of solid and perforated brick, aerated concrete (perforated sleeve WIT-SH, anchor rod WIT-AS, internally threaded sleeve WIT-IG, aerated concrete only with perforated sleeve WIT-SH 18x95)

European Technical Assessment ETA-16/0757 and ETA-20/0854: Individual fixing point + masonry consisting of solid and perforated brick, aerated concrete (perforated sleeve SH, anchor rod W-VI-A, internally threaded sleeve, threaded rod with acceptance test certificate 3.1, aerated concrete only without perforated sleeve)

European Technical Assessment ETA-12/0166: Post-installed rebar connection, 330 ml, 420 ml, 825 ml cartridges only

LAST VIEWED

Added to cart